Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Viruses ; 14(9)2022 09 08.
Article in English | MEDLINE | ID: covidwho-2010318

ABSTRACT

Severe acute respiratory syndrome coronavirus-2 is the causative agent of COVID-19. During the pandemic of 2019-2022, at least 500 million have been infected and over 6.3 million people have died from COVID-19. The virus is pleomorphic, and due to its pathogenicity is often handled in very restrictive biosafety containments laboratories. We developed two effective and rapid purification methods followed by UV inactivation that allow easy downstream handling of the virus. We monitored the purification through titering, sequencing, mass spectrometry and electron cryogenic microscopy. Although pelleting through a sucrose cushion, followed by gentle resuspension overnight gave the best particle recovery, infectivity decreased, and the purity was significantly worse than if using the size exclusion resin Capto Core. Capto Core can be used in batch mode, and was seven times faster than the pelleting method, obviating the need for ultracentrifugation in the containment laboratory, but resulting in a dilute virus. UV inactivation was readily optimized to allow handling of the inactivated samples under standard operating conditions. When containment laboratory space is limited, we recommend the use of Capto Core for purification and UV for inactivation as a simple, rapid workflow prior, for instance, to electron cryogenic microscopy or cell activation experiments.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Proteomics , Sucrose , Virus Inactivation
2.
J Occup Environ Hyg ; 18(8): 394-408, 2021 08.
Article in English | MEDLINE | ID: covidwho-1280000

ABSTRACT

SARS-CoV-2 and other microbes within aerosol particles can be partially shielded from UV radiation. The particles refract and absorb light, and thereby reduce the UV intensity at various locations within the particle. Previously, we demonstrated shielding in calculations of UV intensities within spherical approximations of SARS-CoV-2 virions within spherical particles approximating dried-to-equilibrium respiratory fluids. The purpose of this paper is to extend that work to survival fractions of virions (i.e., fractions of virions that can infect cells) within spherical particles approximating dried respiratory fluids, and to investigate the implications of these calculations for using UV light for disinfection. The particles may be on a surface or in air. Here, the survival fraction (S) of a set of individual virions illuminated with a UV fluence (F, in J/m2) is assumed described by S(kF) = exp(-kF), where k is the UV inactivation rate constant (m2/J). The average survival fraction (Sp) of the simulated virions in a group of particles is calculated using the energy absorbed by each virion in the particles. The results show that virions within particles of dried respiratory fluids can have larger Sp than do individual virions. For individual virions, and virions within 1-, 5-, and 9-µm particles illuminated (normal incidence) on a surface with 260-nm UV light, the Sp = 0.00005, 0.0155, 0.22, and 0.28, respectively, when kF = 10. The Sp decrease to <10-7, <10-7, 0.077, and 0.15, respectively, for kF = 100. Results also show that illuminating particles with UV beams from widely separated directions can strongly reduce the Sp. These results suggest that the size distributions and optical properties of the dried particles of virion-containing respiratory fluids are likely important to effectively designing and using UV germicidal irradiation systems for microbes in particles. The results suggest the use of reflective surfaces to increase the angles of illumination and decrease the Sp. The results suggest the need for measurements of the Sp of SARS-CoV-2 in particles having compositions and sizes relevant to the modes of disease transmission.


Subject(s)
Bodily Secretions/radiation effects , Bodily Secretions/virology , SARS-CoV-2/radiation effects , Ultraviolet Rays , Virion/radiation effects , Aerosols , Air Microbiology , COVID-19/virology , Computer Simulation , Cough/virology , Disinfection/methods , Humans , Sneezing
3.
Viruses ; 13(4)2021 03 26.
Article in English | MEDLINE | ID: covidwho-1154536

ABSTRACT

The risk posed by Severe Acute Respiratory Syndrome Coronavirus -2 (SARS-CoV-2) dictates that live-virus research is conducted in a biosafety level 3 (BSL3) facility. Working with SARS-CoV-2 at lower biosafety levels can expedite research yet requires the virus to be fully inactivated. In this study, we validated and compared two protocols for inactivating SARS-CoV-2: heat treatment and ultraviolet irradiation. The two methods were optimized to render the virus completely incapable of infection while limiting the destructive effects of inactivation. We observed that 15 min of incubation at 65 °C completely inactivates high titer viral stocks. Complete inactivation was also achieved with minimal amounts of UV power (70,000 µJ/cm2), which is 100-fold less power than comparable studies. Once validated, the two methods were then compared for viral RNA quantification, virion purification, and antibody detection assays. We observed that UV irradiation resulted in a 2-log reduction of detectable genomes compared to heat inactivation. Protein yield following virion enrichment was equivalent for all inactivation conditions, but the quality of resulting viral proteins and virions were differentially impacted depending on inactivation method and time. Here, we outline the strengths and weaknesses of each method so that investigators might choose the one which best meets their research goals.


Subject(s)
COVID-19/virology , Disinfection/methods , SARS-CoV-2/radiation effects , Virion/radiation effects , Virus Inactivation/radiation effects , Disinfection/instrumentation , Hot Temperature , Humans , SARS-CoV-2/chemistry , SARS-CoV-2/genetics , SARS-CoV-2/physiology , Ultraviolet Rays , Viral Proteins/genetics , Viral Proteins/metabolism , Virion/chemistry , Virion/genetics , Virion/physiology
4.
J Quant Spectrosc Radiat Transf ; 262: 107489, 2021 Mar.
Article in English | MEDLINE | ID: covidwho-988518

ABSTRACT

UV radiation can inactivate viruses such as SARS-CoV-2. However, designing effective UV germicidal irradiation (UVGI) systems can be difficult because the effects of dried respiratory droplets and other fomites on UV light intensities are poorly understood. Numerical modeling of UV intensities inside virus-containing particles on surfaces can increase understanding of these possible reductions in UV intensity. We model UV intensities within spherical approximations of virions randomly positioned within spherical particles. The model virions and dried particles have sizes and optical properties to approximate SARS-CoV-2 and dried particles formed from respiratory droplets, respectively. In 1-, 5- and 9-µm diameter particles on a surface, illuminated by 260-nm UV light from a direction perpendicular to the surface, 0%, 10% and 18% (respectively) of simulated virions are exposed to intensities less than 1/100th of intensities in individually exposed virions (i.e., they are partially shielded). Even for 302-nm light (simulating sunlight), where absorption is small, 0% and 11% of virions in 1- and 9-µm particles have exposures 1/100th those of individually exposed virions. Shielding is small to negligible in sub-micron particles. Results show that shielding of virions in a particle can be reduced by illuminating a particle either from multiple widely separated incident directions, or by illuminating a particle rotating in air for a time sufficient to rotate through enough orientations. Because highly UV-reflective paints and surfaces can increase the angular ranges of illumination and the intensities within particles, they appear likely to be useful for reducing shielding of virions embedded within particles.

SELECTION OF CITATIONS
SEARCH DETAIL